Section 11 - Maintenance
11.1 Recommended Torque Settings
The torque value for gate seals, the nozzle flange and the inlet tip are
at processing temperature. These should be torqued at ambient (room)
temperature and then re-torqued at processing temperature to the torque
value specified. This is to prevent material leakage from the gate seal.
Torque sequence and step torquing:
Mold-Masters
recommends that manifold
mounting screws be torqued in a standard bolt pattern and that the specified
torque is achieved in 3 steps (1/3, 2/3 and full torque).
Quality and length of screws must be as specified on
Mold-Masters
General
Assembly drawings.
WARNING
Ensure that you have fully read “Section 3 - Safety” before doing
maintenance procedures on your FUSION SERIES
®
G2 system.
11-1
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
MAINTENANCE
FSG2 User Manual
Summary of Contents for Fusion G2
Page 1: ...version 14 User Manual Original Instructions...
Page 2: ......
Page 10: ......
Page 64: ......
Page 151: ......