5.5 Assemble Nozzle to Manifold
11. Apply anti-seize compound to the nozzle threads.
12. Assemble the nozzle to the manifold.
13. Torque the nozzles to value on the General Assembly drawing.
IMPORTANT
Remember to re-torque at process temperature when system assembly is
complete.