5.8 Gate Seal and Nozzle Assembly
5.8.1 Check Gate Seal to Nozzle Fit
1. Apply die spotting blue compound to the gate seal and gate seal liner (if
relevant).
2.
Torque the gate seal to specified value.
3. Remove gate seal and verify transfer of die spotting blue compound from
gate to the liner. Verify transfer of die spotting blue compound to nozzle
core. If not 100% blue on face, contact your
Mold-Masters
representative.
4. Clean die spotting blue compound from components.
5-19
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.