6.4.2 SE40-20C Actuator - Cooled
CAUTION
For the cooled model of the SeVG Plus actuator, the maximum operating
temperature for the actuator plate and the top spacer plates is 200°C
(392°F).
Ensure that the SeVG Plus actuator is not dropped at any time, as damage
to its connectors and internal parts may lead to the failure of the actuator.
CAUTION
IMPORTANT
Mold-Masters
assumes no responsibility for connection, monitoring and / or
maintenance of any cooling system associated with an SeVG Plus system.
1. Valve pin
2. Valve pin holder (bottom)
3. Valve pin holder (top)
4. Motor rod
5. Motor locating spigot
6. Motor mount flange
7. SHCSM6X25
8. Motor
9. Water fittings
1
2
3
4
6
7
8
5
9
Figure 6-2 SE40-20C actuator
6-3
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
SEVG PLUS ACTUATOR
FSG2 User Manual