45
D
ESK
T
OP
S
ERIES
–
AUTOMATIC OPERATION
HEAD:
ERROR
DESCRIPTION
CHECK
Head must be in upper/lower
position within # seconds
Air pressure
Sensors head
Working head
Head is in lower position
while slide activated
Working fire-switch
Z-movement head
Sensors slide
Wiring / connectors
SLIDE:
ERROR
DESCRIPTION
CHECK
Slide must be in front/rear
position within # seconds
Air pressure
Sensors slide
Working slide
Slide is in rear position while
head activated
Working fire-switch
Z-movement head
Sensors slide
Wiring / connectors
TAPE:
ERROR
DESCRIPTION
CHECK
Tape-end sensor is activated;
tape is empty or broken.
Tape
Tape-end sensor
*LIGHTCURTAIN:
ERROR
DESCRIPTION
CHECK
Only in production mode!
Light curtain is interrupted.
*Light curtain message will only appear in production mode, NOT in service mode and when
firing switch is activated (start Uniflow) in production mode.