23
D
ESK
T
OP
S
ERIES
–
AUTOMATIC OPERATION
3.
Remove the cable tie from the head.
4.
Do a check of the installation area.
5.
Install the machine on a level surface and locate the units in an orderly manner.
CAUTION
The cables must be connected correctly to ensure optimal current
flow.
6.
Remove the Uniflow cable cover, if applicable.
7.
Clean the cable connectors.
8.
Connect the two thermode power cables. Make sure you connect them with the correct
nuts and washers.
9.
Connect the system and the Uniflow to the electrical power supply. The unit requires
one of the following power sources, depending on the country:
- 230 Vac 50/60 Hz 1-Phase power supply (Europe)
- 208 Vac 50/60 Hz 2- Phase power supply (US)
- 120 Vac 50/60 Hz 1- Phase power supply (US).
NOTE:
The supply must be protected by fuses. Before switching on the
unit, make sure the voltage and frequency given on the type label
of the unit are in accordance with the local power supply
NOTE:
If constant heat control is installed, the TTM-04 control panel is as
shown below. If this is installed, it is essential that the earth
connection of the controller is connected to the thermode.