36
D
ESK
T
OP
S
ERIES
–
AUTOMATIC OPERATION
7.
Check the operation of the micro switch PLC input (LED light) in the process
position.
4.3.3.4
Sensor adjustment
1.
Turn the turntable clockwise to position 1.
2.
Loosen screw 1A.
3.
Adjust the sensor until it is in the middle of the margin (see figure 22).
4.
Check the operation of the sensor PLC input (LED light) position 1.
5.
Tighten screw 1A.
6.
Turn the turntable counter-clockwise to position 2.
7.
Loosen screw 1B.
8.
Adjust correct sensor until it is in the middle of the margin.
9.
Check the operation of the sensor PLC input (LED light).
10.
Tighten screw 1B.
Margin
Margin
1A
1B