AUTOMATIC OPERATION
10.
Connect the unit to the compressed air system. The connection is located at the right
rear of the Desktop system.
11.
Make sure the unit is supplied with constant dry, clean air (6 +/- 0.5 bar). The system
will work at a minimum pressure of 5.0 bar, but the pressure must not go below this
level. A shut off valve must be used to isolate the Desktop system from the
compressed air system.
12.
For DT-350, DT-360 and DT-370 systems, if the system is delivered without product
supports, make sure you remove the shipping bolt.
13.
For DT-450 systems, if the system is delivered without product supports, make sure
you remove the shipping bolt.
14.
If the customer product supports are installed, remove the cable ties that lock the
turntable or fixtures and shipping bolt..
After completion of the installation and adjustment of the system, all the employees
concerned must be trained by the installer with regard to:
- construction
- supervision
- functioning of the system
- maintenance
Shipping bolt
Shipping bolt