
[
X
LED Monitor Display on the Outdoor Unit Board ]
- 359 -
HWE09130
ILE
D
M
o
n
ito
r D
is
p
la
y
on
th
e
O
u
td
oo
r U
n
it
Bo
ar
d
L
E
D
mo
ni
tor
di
s
p
la
y
C
u
rrent
dat
a
No
.
SW1
Ite
m
Disp
la
y
Unit
(A
, B)
*1
Re
m
a
rk
s
12
34
567
89
0
L
D1
LD
2
L
D3
LD4
L
D5
L
D6
L
D7
LD
8
O
C
OS
0
00
00
000
00
0
Re
la
y ou
tput
di
sp
lay 1
Li
g
ht
ing
Comp
in
o
p
-
er
at
ion
72
C
O
C
CPU in op
er
-
at
io
n
AA
Ch
ec
k (e
rr
or
) d
is
pl
ay
1
OC/OS
error
00
0
0
t
o
99
99
(A
d
d
re
s
s
an
d er
ro
r
c
o
de
s hig
h
lig
ht
ed
)
B
B
1
10
00
000
00
0
Ch
ec
k (e
rr
or
) d
is
pl
ay
2
OC/OS
error
00
0
0
t
o
99
99
(A
d
d
re
s
s
an
d er
ro
r
c
o
de
s hig
h
lig
ht
ed
)
A
A
Di
sp
la
y of th
e
lat
es
t
p
re
-
limin
a
ry
er
ro
r
If n
o
pr
el
imin
ar
y
er
ro
rs
ar
e d
e
tec
te
d,
"
--
--"
a
p
-
pe
ar
s on
th
e di
sp
la
y.
2
01
00
000
00
0
Ch
ec
k (e
rr
or
) d
is
pl
ay
3
(I
nc
lu
din
g
IC
a
n
d
B
C
)
0
0
0
0
t
o
99
99
(A
d
d
re
s
s
an
d
er
ro
r c
o
de
s
hig
h
lig
ht
ed
)
B
If
no e
rr
or
s ar
e de
tect
e
d,
"-
--
-"
a
ppe
ar
s on
th
e di
s-
pla
y
.
3
11
00
000
00
0
Re
la
y ou
t-
p
u
t di
sp
la
y
2
T
o
p
2
1S4
a
CH11
S
V1a
SV2
AA
Bo
tto
m
21
S4b
S
V5b
4
00
10
000
00
0
Re
la
y ou
t-
p
u
t di
sp
la
y
3
To
p
SV
4a
SV4
b
SV
4
c
SV
5
c
SV
4
d
SV9
Pow
er
s
up
-
pl
y fo
r i
ndo
or
tr
an
s
m
is-
s
ion l
ine
AA
Bo
tto
m
52
F
5
10
10
000
00
0
6
01
10
000
00
0
7
11
10
000
00
0
Sp
ec
ia
l c
o
n
tr
o
l
Ret
ry op
er
a-
ti
on
Emer
ge
nc
y
o
per
at
ion
Communica-
ti
on
e
rr
or
be-
tw
ee
n t
he
OC an
d OS
Communica-
ti
o
n
er
ro
r
3-
mi
nu
te
r
e-
s
tar
t de
lay
mode
BB
8
00
01
000
00
0
9
10
01
000
00
0
Commu
ni
ca
tio
n
de
-
ma
nd
c
apa
ci
ty
00
00
t
o
9
99
9
B
If
not
de
man
ded
con
-
tro
lle
d
, "
----
"
[ %
] a
p
-
pe
ar
s on
th
e di
sp
la
y.
10
01
01
000
00
0
Co
nt
ac
t p
oi
nt
dema
nd
ca
pa
ci
ty
00
00
t
o
9
99
9
B
If
not
de
man
ded
con
-
tro
lle
d
, "
----
"
[ %
] a
p
-
pe
ar
s on
th
e di
sp
la
y.
*1 A:
Th
e co
ndi
ti
on o
f ei
the
r OC o
r OS i
s di
sp
laye
d i
nd
iv
id
ua
lly
. B:
Th
e co
ndi
ti
on o
f t
he
e
nt
ire
r
ef
rig
er
an
t sy
st
e
m
i
s d
is
pl
ay
e
d.
Summary of Contents for PURY-P120
Page 1: ...Models PURY P72 P96 P120 P144T Y JMU A PURY P168 P192 P216 P240 P264 P288T Y SJMU A ...
Page 11: ... 2 ...
Page 25: ... 16 ...
Page 36: ... II Restrictions 27 HWE09130 GB ...
Page 50: ... II Restrictions 41 41 HWE09130 GB ...
Page 67: ... 58 II Restrictions GB HWE09130 ...
Page 69: ... 60 ...
Page 95: ... 86 III Outdoor Unit Components GB HWE09130 ...
Page 97: ... 88 ...
Page 105: ... 96 IV Remote Controller GB HWE09130 ...
Page 107: ... 98 ...
Page 125: ... 116 ...
Page 145: ... 136 ...
Page 175: ... 166 VII Control GB HWE09130 ...
Page 177: ... 168 ...
Page 203: ... 194 ...
Page 363: ... 354 IX Troubleshooting GB HWE09130 ...
Page 365: ... 356 ...