6 - 12
6. DISPLAY AND OPERATION
6.8 Test operation mode
CAUTION
y
The test operation mode is designed to confirm servo operation and not to confirm
machine operation. In this mode, do not use the servo motor with the machine.
y
If any operational fault has occurred, stop operation using the forced stop (EMG)
signal.
POINT
y
The Servo Configuration software is required to perform positioning
operation.
6.8.1
Mode change
Call the display screen shown after power-on. Choose jog operation/motor-less operation in the following
procedure:
Press MODE once.
⋅⋅⋅⋅⋅⋅
When this screen
appears, jog feed can
be performed.
Press UP three times.
Press SET for more than
2s.
Flickers in the test operation mode.
Press UP five times.
Press SET for more than 2s.
⋅⋅⋅⋅⋅⋅
When this screen is displayed,
motor-less operation can be
performed.