7. HG-SN SERIES
7 - 4
7.3.2 Torque characteristics
POINT
For the system where the unbalanced torque occurs, such as a vertical axis
system, the unbalanced torque of the machine should be kept at 70% or lower of
the motor's rated torque.
When the power supply input of the servo amplifier is 3-phase 200 V AC or 1-phase 230 V AC, the torque
characteristic is indicated by the heavy line. HG-SN52, HG-SN102, HG-SN152, and HG-SN202 support
single-phase power supply.
[HG-SN52]
Speed [r/min]
T
orque [
N
•m]
1000
2000
3000
0
0
3
9
6
Continuous
running range
Short-duration
running range
[HG-SN102]
Speed [r/min]
T
orque [
N
•m]
1000
2000
3000
0
0
5
15
10
Continuous
running range
Short-duration
running range
[HG-SN152]
Speed [r/min]
T
orque [
N
•m]
1000
2000
3000
0
0
8
24
16
Short-duration
running range
Continuous
running range
[HG-SN202]
Speed [r/min]
T
orque [
N
•m]
1000
2000
3000
0
0
10
30
20
Continuous
running range
Short-duration
running range
[HG-SN302]
Speed [r/min]
T
orque [
N
•m]
1000
2000 2500
0
0
15
45
30
Continuous
running range
Short-duration
running range
Summary of Contents for HG-KN
Page 15: ...1 INTRODUCTION 1 6 MEMO ...
Page 23: ...2 INSTALLATION 2 8 MEMO ...
Page 37: ...4 CONNECTION OF SERVO AMPLIFIER AND SERVO MOTOR 4 8 MEMO ...
Page 59: ...5 WIRING OPTION 5 22 MEMO ...
Page 77: ...6 HG KN SERIES 6 18 MEMO ...
Page 89: ...7 HG SN SERIES 7 12 MEMO ...
Page 101: ...MEMO ...