4. CONNECTION OF SERVO AMPLIFIER AND SERVO MOTOR
4 - 1
4. CONNECTION OF SERVO AMPLIFIER AND SERVO MOTOR
WARNING
Any person who is involved in wiring should be fully competent to do the work.
Ground the servo motor securely.
Do not attempt to wire the servo motor until it has been mounted. Otherwise, it
may cause an electric shock.
The cables should not be damaged, stressed, loaded, or pinched. Otherwise, it
may cause an electric shock.
To avoid an electric shock, insulate the connections of the power supply
terminals.
CAUTION
Wire the equipment correctly and securely. Otherwise, the servo motor may
operate unexpectedly, resulting in injury.
Connect cables to the correct terminals. Otherwise, a burst, damage, etc. may
occur.
Ensure that polarity (+/-) is correct. Otherwise, a burst, damage, etc. may occur.
Do not install a power capacitor, surge killer or radio noise filter (optional FR-BIF)
with the power line of the servo motor.
Do not modify the equipment.
Connect the servo amplifier power output (U/V/W) to the servo motor power input
(U/V/W) directly. Do not let a magnetic contactor, etc. intervene. Otherwise, it may
cause a malfunction.
U
Servo motor
M
V
W
U
V
W
U
M
V
W
U
V
W
Servo amplifier
Servo motor
Servo amplifier
Before wiring, switch operation, etc., eliminate static electricity. Otherwise, it may
cause a malfunction.
Summary of Contents for HG-KN
Page 15: ...1 INTRODUCTION 1 6 MEMO ...
Page 23: ...2 INSTALLATION 2 8 MEMO ...
Page 37: ...4 CONNECTION OF SERVO AMPLIFIER AND SERVO MOTOR 4 8 MEMO ...
Page 59: ...5 WIRING OPTION 5 22 MEMO ...
Page 77: ...6 HG KN SERIES 6 18 MEMO ...
Page 89: ...7 HG SN SERIES 7 12 MEMO ...
Page 101: ...MEMO ...