86
Inspection Item
•
Reinstallation
1)After confirming the orientation of the fan, reinstall the fan so that the arrow on the left of "AIR FLOW" faces up.
2)Reconnect the fan connectors.
When wiring, use care to avoid the cables being caught by the fan.
3) Reinstall the fan cover.
AIR FLOW
<Fan side face>
CAUTION
Installing the fan in the opposite air flow direction can cause the inverter life to be shorter.
FR-F720-00340 to 00630
FR-F740-00170 to 00380
FR-F720-00105 to 00250
FR-F740-00083, 00126
FR-F720-01250
FR-F720-00770, 00930
FR-F740-00470, 00620
FR-F720-01540 to 02330
FR-F740-00770 to 03610
2. Insert hooks until
you hear a click
sound.
1. Insert hooks into
holes.
FR-F720-00105 to 00250
FR-F740-00083, 00126
2. Insert hooks until
you hear a click
sound.
1. Insert hooks into
holes.
FR-F720-00340 to 01250
FR-F740-00170 to 00620
2. Insert hooks until
you hear a click
sound.
1. Insert hooks into
holes.
FR-F720-01540 to 02330
FR-F740-00770 to 03610