84
Inspection Item
6.1.7
Replacement of parts
The inverter consists of many electronic parts such as semiconductor devices.
The following parts may deteriorate with age because of their structures or physical characteristics, leading to
reduced performance or fault of the inverter. For preventive maintenance, the parts must be replaced periodically.
Use the life check function as a guidance of parts replacement.
* Replacement years for when the yearly average ambient temperature is 40°C (104°F)
(without corrosive gas, flammable gas, oil mist, dust and dirt etc)
(1) Cooling fan
The replacement interval of the cooling fan used for cooling the parts generating heat such as the main circuit
semiconductor is greatly affected by the ambient temperature. When unusual noise and/or vibration is noticed
during inspection, the cooling fan must be replaced immediately.
The FR-F720-00046, 00077, FR-F740-00023 to 00052 are not provided with a cooling fan.
Part Name
Standard Replacement
Interval*
Description
Cooling fan
10 years
Replace (as required.)
Main circuit smoothing capacitor
10 years
Replace (as required.)
On-board smoothing capacitor
10 years
Replace the board (as required)
Relays
-
as required.
CAUTION
For parts replacement, consult the nearest Mitsubishi FA Center.
Inverter Type
Fan Type
Units
200V
class
00105 to 00250
MMF-06F24ES-RP1 BKO-CA1638H01
1
00340 to 00630
MMF-08D24ES-RP1 BKO-CA1639H01
2
00770, 00930
MMF-12D24DS-RP1 BKO-CA1619H01
1
01250
MMF-06F24ES-RP1 BKO-CA1638H01
1
MMF-12D24DS-RP1 BKO-CA1619H01
1
01540
MMF-09D24TS-RP1 BKO-CA1640H01
2
01870, 02330
MMF-12D24DS-RP1 BKO-CA1619H01
2
400V
class
00083, 00126
MMF-06F24ES-RP1 BKO-CA1638H01
1
00170, 0380
MMF-08D24ES-RP1 BKO-CA1639H01
2
00470, 00620
MMF-12D24DS-RP1 BKO-CA1619H01
1
00770
MMF-09D24TS-RP1 BKO-CA1640H01
2
00930 to 01800
MMF-12D24DS-RP1 BKO-CA1619H01
2
02160 to 03610
3