60
Parameter copy
4.9 Parameter copy
Multiple inverters and parameter settings can be copied.
appears...Why?
Parameter read error. Perform operation from step 3 again.
appears...Why?
Parameter write error. Perform operation from step 8 again.
and
flicker alternately
Appears when parameters are copied between the inverter of 200V class, FR-F740-01160 or less and FR-
F740-01800 or more.
1. Set "0" in
Pr. 160 User group read selection
.
2. Set the following setting (initial value) in
Pr. 989 Parameter copy alarm release
.
3. Reset
Pr.9, Pr.30, Pr.51, Pr.52, Pr.54, Pr.56, Pr.57, Pr.61, Pr.70, Pr.72, Pr.80, Pr.90, Pr.158, Pr.190 to Pr.196, Pr.893
.
PCPY Setting
Description
0
Cancel
1
Copy the source parameters to the operation panel.
2
Write the parameters copied to the operation panel into
the destination inverter.
3
Verify parameters in the inverter and operation panel.
(Refer to page 61.)
1.
Connect the operation panel to the
copy source inverter.
•
Connect it during a stop.
Display
Operation
2.
Press to choose the parameter
setting mode.
Flicker ··· Parameter copy complete!!
6.
Press to copy the source parameters
to the operation panel.
4.
Press to to read the currently set value.
" "(initial value) appears.
Flicker ··· Parameter copy complete!!
9.
Press to write the parameters copied to
the operation panel to the destination inverter.
3.
Turn until (parameter copy)
appears.
5.
Turn clockwise to change it to
the setting value of " ".
The frequency flickers
for about 30s
The frequency flickers
for about 30s
About 30s later
10.
When copy is completed,
" " and " " flicker.
11.
After writing the parameter values to the copy
destination inverter, always reset the inverter,
e.g. switch power off once, before starting operation.
7.
Connect the operation panel to the
copy source inverter.
8.
After performing steps 2 to 5,
turn clockwise to change
it to " ".
The parameter
number previously
read appears.
200V class and FR-F740-01160 or less
FR-F740-01800 or more
Pr. 989 Setting
10
100
REMARKS
· When the copy destination inverter is not the FR-
F700 series, "model error (
)" is displayed.
· Refer to the extended parameter list on
page 102
for
availability of parameter copy.
Summary of Contents for FR-F700 Series