4 ADJUSTMENT
4.1 Simple mode parameter list
For simple variable-speed operation of the inverter, the initial setting of the parameters may be used as they are. Set the
necessary parameters to meet the load and operational specifications. Parameter setting, change and check can be made
from the operation panel (FR-DU07). For details of parameters, refer to the
Instruction Manual (applied)
.
Display the simple mode parameters.
Pr. 160
Description
9999
Only the simple mode parameters can be displayed.
0
(Initial Value)
Simple mode and extended mode parameters can be displayed.
1
Only the parameters registered in the user group can be displayed.
Error display?
If the operation panel does not have the write precedence
REMARKS
If the setting has not been changed, the value does not flicker and the next parameter number appears.
1.
Screen at powering on
The monitor display appears.
Display
Operation
3.
Press to choose the parameter
setting mode.
4.
Turn until (
Pr. 160
)
appears.
Flicker ··· Parameter setting complete!!
7.
Press to set.
PU indication is lit.
2.
Press to choose
the PU operation mode.
·
Press twice to show the next parameter.
·
By turning , you can read another parameter.
·
Press to show the setting again.
The parameter
number read
previously appears.
After parameter setting is completed, press once to show the alarm history and
press twice to return to the monitor display. To change settings of other parameters,
perform the operation in above steps 3 to 7.
5.
Press to read the currently set value.
" " (initial value) appears.
6.
Turn to change it to the set value
of " ".