58
Using
Pr.190 to Pr.196
, output signals assigned to the device numbers can be changed.
For the details of
Pr.190 to Pr.196
, refer to the Instruction Manual (Detailed) of the inverter.
If the value to be read exceeds two bytes, 0xFFFF is returned to the master.
Format for 16-bit data
(32Bit Format (Bit7 of Byte1) = 0)
Format for 32-bit data
(32Bit Format (Bit7 of Byte1) = 1)
Byte2
Byte3
• Hz bit of Instance 127 (Bit6 of Byte1) = 0
Inverter running speed (1 r/min increments)
The setting values of
Pr.37, Pr.144, and Pr.811
are effective. (Refer to
)
• Hz bit of Instance 127 (Bit6 of Byte1) = 1
Output frequency (0.01 Hz increments)
Byte4
Byte5
Read data 1
Read value of the attribute specified by Byte6 and Byte7 of
Instance 127
When an unsupported attribute is specified, 0 is returned.
Read data 1
Read value of the attribute specified by Byte6 and Byte7 of
Instance 127
When an unsupported attribute is specified, 0 is returned.
Byte6
Byte7
Read data 2
Read value of the attribute specified by Byte4 and Byte5 of
Instance 127
When an unsupported attribute is specified, 0 is returned.