26
Set
Pr.346
according to the baud rate and Output/Input Instances (number of bytes of communicated data) of the I/O
communication as shown in the following table.
2 to 6
Output Assembly
1
0
Output Instance 20 (0x14)
• Set the same value for input
assembly and output assembly.
• The value can be set with Control
Supervisor Class 0x29 Instance 1
Attribute 140, 141.
(Refer to
)
1
Output Instance 21 (0x15)
6
Output Instance 126 (0x7E)
7
Output Instance 127 (0x7F)
8, 14
For manufacturer setting. Do
not set.
Other than the above
Output Instance 21 (0x15)
7 to 11
Input Assembly
1
0
Input Instance 70 (0x46)
1
Input Instance 71 (0x47)
6
Input Instance 176 (0xB0)
7
Input Instance 177 (0xB1)
8, 14
For manufacturer setting. Do
not set.
Other than the above
Input Instance 71 (0x47)
12 to 15
Reserved
0
0
Set "0" always.
Baud rate
Output/Input Instances (No. of bytes of communicated data) of the I/O communication
20/70 (4)
21/71 (4)
126/176 (6)
127/177 (8)
125 kbps
0, 3
132 (initial value), 135
792, 795
924, 927
250 kbps
1
133
793
925
500 kbps
2
134
794
926
Bit
Item
Initial
value
Setting range
Definition