69
7
Class 0x05 Instance 4, 5, 6 attribute (Explicit messaging connection)
Class 0x05 Instance 4, 5, 6
Attribute
ID
Access
Name
Data
type
No. of
data bytes
Range
Definition
1
Get
State
USINT
1
00
Non-existent
01
Configuring
03
Established
04
Timed out
2
Get
InstanceType
USINT
1
00 Explicit
messaging
connection
3
Get
Transport Trigger
class
BYTE
1
00 to 0xFF
0x83: Server Transport Class 3
4
Get
Produced
Connection ID
UINT
2
0 to 0xFFFF
CAN ID that the inverter sends
5
Get
Consumed
Connection ID
UINT
2
0 to 0xFFFF
CAN ID that the inverter receives
6
Get
Initial Command
Characteristics
BYTE
1
00 to 0xFF
The value defines sent and received message
groups.
0x33: Both send and receive messages are
Group 2 message
7
Get
Produced
Connection Size
UINT
2
0 to 0xFFFF
This value specifies the maximum number of
Message Body bytes that a module is able to
transmit across the connection.
7: 7 bytes
8
Get
Consumed
Connection Size
UINT
2
0 to 0xFFFF
This value specifies the maximum number of
Message Body bytes that a module is able to
receive across the connection.
7: 7 bytes