138
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Specifications
Rated Power Supply:
100 to 240 V AC, 50/60 Hz
Rated Input:
1.0 - 0.45 A (100-240 V)
Colour System:
NTSC-type colour system.
Operating Temperature:
41
°
F-104
°
F (5
°
C to 40
°
C)
Relative Humidity:
Max. 80 (%)
Altitude:
Max. 2000 (m)
Dimensions:
425 (Width) x 390 (Depth) x 185 (Height) (mm)
Weight:
12.9 kg
Recording System
Digital recording system
Sampling
13.5 MHz
Data Compression
JPEG2000
Compression Unit
Frame, Field
Recording Resolution
720 x 480, 720 X 240
Recording Device
Hard disc drive
Video Input:
16 Input BNC-Connectors:
1.0 V(p-p), 75 ohms.
Monitor Output:
S-Connector:
Y-Signal: 1.0 V(p-p), 75 ohms.
C-Signal: 0.286 V(p-p), 75 ohms.
2 Output BNC-Connectors:
1.0 V(p-p), 75 ohms.
RCA-jack:
1.0 V(p-p), 75 ohms.
Throughout Output:
16 Output BNC-Connectors: 1.0 V(p-p), 75 ohms.
Cascade Video Input:
BNC-Connector:
1.0 V(p-p), 75 ohms.
Cascade Video Output:
BNC-Connector:
1.0 V(p-p), 75 ohms.
Audio Input:
4 RCA-Jacks:
308 mV(rms), 50 k ohms.
Audio Output:
RCA-Jack:
308 mV(rms), 1 k ohms.
Cascade Audio Input:
RCA-Jack:
308 mV(rms), 50 k ohms.
Cascade Audio Output:
RCA-Jack:
308 mV(rms), 1 k ohms.
Clock:
±
20 seconds/month (when power is supplied, 25
°
C)
Timer Program:
8 programs-Daily start and stop time for one week x 2 set
Memory Backup:
Lasts for more than 1 month (when fully charged)
CONNECTORS
External storage terminal
Serial bus (1-6)
Bus power Max. 10 W in total
(For connecting the recommended optional items only)
Control terminals
Clock adjust Input
Active: When terminals are short-circuited or “Low” Level voltage is applied. Non active: Open.
Clock adjust Output
Active: When terminals are short-circuited or “Low” Level voltage is applied. Non active: Open.
(Clock adjust Output is throughout of Clock adjust Input)
Recording start Input
Active: When terminals are short-circuited or “Low” Level voltage is applied. Non active: Open.
Recording stop Input
Active: When terminals are short-circuited or “Low” Level voltage is applied. Non active: Open.
Emergency Input
Active: When terminals are short-circuited or “Low” Level voltage is applied. Non active: Open.
Mode out +/– (1-4)
Active:
Short
Max. Drive current 500 mA DC.
(Relay output)
Non active:
Open.
Max. Voltage 24 V DC.
Call out +/–
Active:
Short
Max. Drive current 7 mA DC.
(Photo coupler output)
Non active:
Open.
Max. Voltage 24 V DC.
Ground terminal
DC 12 V Output
Max. 350 mA DC (when Main switch and power button is turned on)
Alarm Input (1-16)
Active: When terminals are short-circuited or “Low” Level voltage is applied. Non active: Open.
Alarm Output (1-16)
Active:
“Low” Level
Max. Drive current 7 mA DC.
Non active:
Open.
Max. Voltage 24 V DC.
PTZ terminal
RS-232C terminal
RS-422 terminal
Serial port
RS-232C D-SUB 9 pin
RS-485 port
RS-485 Input/Output RJ-11
Communication
LAN (A, B)
Connector form: RJ-45 Physical interface: 10BASE-T/100BASE-TX
(A for external storage, B for communication)
Card slot for optional board
PCI-compliant slot type (low profile) (For connecting the recommended optional items only)
DVD-R/RW, CD-R/RW recording format
Original format
Accessories:
AC power cord
1
Screws
8
CD
1
Mouse
1
Cable clamping band
2
Ferrite core
1
Installer’s manual (this manual)
1
User’s manual
1
Weight and dimensions shown are approximate.
Design and specifications are subject to change without notice.
Specifications
Summary of Contents for 16CH DIGITAL RECORDER DX-TL5000U