5 )# 7*
)6)
() 5))
% (
10 Close the two green lock levers.
11 Close the printer’s top cover.
12 If you have a duplexer, close the
duplexer’s rear cover.
13 Turn on the printer.
14 Reset the consumables usage moni-
toring system.
a
In the Operator Control/
Consumables/Item Replaced/
Fuser Oil menu choose Yes.
b
In the Operator Control/
Consumables/Item Replaced/
Cleaning Roller menu choose Yes.
»
Note:
When you replace the fuser oil bottle and cleaning roller after a
FUSER OIL
EMPTY
or
CHECK CLEANING ROLLER
message displays in the message window,
the engine automatically recovers. However, you must manually reset the
consumables usage monitoring system to ensure accurate consumables
monitoring.
To access consumables usage information, use the Operator Control/Consum-
ables/Print Statistics menu or the CrownView printer web page.