Bytes 0 63
Name
Type of data
Function
Byte 3
Material ID
BYTE
Value range: 1 10
Byte 4 7
Set point
DINT/REAL
Weight
Byte 8 11
Preset
DINT/REAL
Preset point for switching from coarse flow
to fine flow.
Byte 12 15
Material overshoot (OVS)
DINT/REAL
Weight
Byte 16 19
Calming time
DINT
[ms]
Byte 20 23
Tolerance above set point
DINT/REAL
Weight
Byte 24 27
Tolerance below set point
DINT/REAL
Weight
12.3.5.2
Read window EasyFill → PLC
The data required for monitoring and controlling filling does not fit in a 64-byte write
window. For this reason the system differentiates between system and material
parameters. The value of the first byte can be used to determine whether the data refers
to the system or the material.
12.3.5.2.1 System data
Before starting filling, a check must be carried out to ensure that the system is ready
(byte 3: bit 2).
The Dosing_Run bit is set once filling has successfully started.
Bytes 0 63
Name
Type of data
Function
Byte 0
TableSelect
USINT
Content of read data:
0 = system data, 1 = material data
Byte 1
Bit 0: MSB
Bit 0: ADC error
Bit 1: above max. + still permis-
sible range (OVL)
Bit 2: above max. (FSD)
Bit 3: below zero
Bit 4: zero ±¼ d
Bit 5: within zero set range (ZSR)
Bit 6: weight is stable
Bit 7: weight above max. (FSD)
and below overload
BOOL
Transmitter Series PR 5220
12 Fieldbus interface
Minebea Intec
EN-206