SPM address
Type of data
R/W
Function
D10
DINT
R
Current tare weight
D11
DINT
R
Current gross/net weight selected with X72
D14
DINT
R
Max. weight (FSD)
D15
DINT
R
Min. weight
D16
DINT
R
Report: Gross weight
D17
DINT
R
Report: Net weight
D18
DINT
R
Report: Tare weight
D19
DINT
R
Report: Sequence number
D21
DINT
R
Report: Date
D22
DINT
R
Report: Time
D23
DINT
R
Activity counter, test of communication with device
D24
DINT
R
Standard application only: Limit: Limit 1 on
D25
DINT
R
Standard application only: Limit: Limit 1 off
D26
DINT
R
Standard application only: Limit: Limit 2 on
D27
DINT
R
Standard application only: Limit: Limit 2 off
D28
DINT
R
Standard application only: Limit: Limit 3 on
D29
DINT
R
Standard application only: Limit: Limit 3 off
D30
UDINT
R/W
Standard application only: Analog output for "transparent" mode
D31
DINT
R/W
Write the value in the preset tare memory.
B144
X1152
X1153
X1154
X1155
BYTE
BOOL
BOOL
BOOL
BOOL
R
R
R
R
R
EasyFill only:
Filling status 1
Filling mode active
Filling mode ready (ready/idle)
Filling mode error
Filling mode in setup
B145
X1160
X1161
X1162
X1163
X1164
X1165
BYTE
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
R
R
R
R
R
R
R
EasyFill:
Filling status 2
Filling in progress
Filling paused
Coarse flow
Fine flow
Calming
Tolerance alarm
Transmitter Series PR 5220
13 SPM
Minebea Intec
EN-214
Summary of Contents for PR 5220 Series
Page 234: ......