PR 5220/00 switch settings
PR 5220/00 configuration
ON: S1, S3
OFF: S2
S4 not relevant
- [Serial ports parameter]- [xBPI-Port]- [Builtin RS-485]
Note:
For further information, see the installation manuals relating to the load cells and junction boxes.
4.4.4
Analog outputs
The device is equipped with an integral analog output. The interface can be configured by
software.
Specifications
Description
Data
Connection
Terminal, 4-pin
Output: Qty
1 active current output:
0/4 20 mA (max. 24 mA), 10 V output voltage via external
500
resistor
Output: Function
Gross/net weight or via ProfiBus
Output: Range
0/4 20 mA, configurable
Output: Resolution
e.g. 0 20 mA in max. 40,000 parts
Output: Linearity error
@ 0 20 mA: <0.05 %
@ 4 20 mA: <0.025 %
4 Device installation
Transmitter Series PR 5220
EN-33
Minebea Intec
Summary of Contents for PR 5220 Series