Bytes 0 63
Name
Type of data
Function
Byte 31
Reserved
Byte 32 35
Gross filling result
DINT/REAL
Byte 36 39
Tare filling result
DINT/REAL
Byte 40 43
Net filling result
DINT/REAL
Byte 44 47
Set point filling result
DINT/REAL
The filling results are stored after filling and
only overwritten when there is a new result.
Byte 48 51
Date of filling result
DINT
Example:
20161116h corresponds to November 16,
2016
Byte 52 55
Time of filling result
DINT
Example:
14153199h corresponds to 14:15:31 and
99 ms
Byte 56 59
Sequence number of filling re-
sult
DINT
Sequential number
Byte 60
Filling result status
BYTE
1 = successful, 2 = tolerance alarm, 3 = can-
celed
Byte 61 62
Reserved
Byte 63
"Last_Error" error
The last error number is retained until it is
reset (for possible errors see Chap-
ter
12.3.5.2.2 Material data
The first 15 bytes and byte 63 (Last_Error) correspond to the layout of the system data.
Bytes 0 63
Name
Type of data
Function
Byte 0
TableSelect
USINT
Content of read data:
0 = system data, 1 = material data
Byte 1
Bit 0: MSB
Bit 0: ADC error
Bit 1: above max. + still permis-
sible range (OVL)
Bit 2: above max. (FSD)
Bit 3: below zero
Bit 4: zero ±¼ d
Bit 5: within zero set range (ZSR)
Bit 6: weight is stable
Bit 7: weight above max. (FSD)
and below overload
BOOL
Transmitter Series PR 5220
12 Fieldbus interface
Minebea Intec
EN-208
Summary of Contents for PR 5220 Series
Page 234: ......