![MIMAKI JV5-320S Operation Manual Download Page 35](http://html.mh-extra.com/html/mimaki/jv5-320s/jv5-320s_operation-manual_1800291035.webp)
1-23
Basic specifications
Notes on USB 2.0 Interface
When two or more JV5 printers are connected to one personal computer
When two or more JV5 printers are connected to one personal computer, the personal computer may not
recognize all the JV5 printers normally.
Reconnect the unrecognized JV5 printer to another USB port, if available, and check to see if it is recog-
nized. If the JV5 printer is not recognized even through the newly connected USB port, use USB 2.0
repeater cables available on the market.
Notes on peripheral devices in USB high speed mode
When a peripheral device (USB memory or USB HDD) to be operated in USB high speed mode is con-
nected to the same personal computer that a JV5 printer is connected to, the USB device may not be recog-
nized.
When a JV5 printer is connected to the personal computer to which an externally installed USB hard disk
drive is connected, the data output speed to the JV5 printer may drop. That can cause the head unit to stop
temporarily at the right or left end during printing.
Removing USB memory
If a USB memory module is inserted in the personal computer to which a JV5 printer is connected, click
“Stop” in the “Safely Remove Hardware” window by following the instructions given there first and then
remove the module. Leaving a USB memory module inserted can cause [ERROR 10 COMMAND
ERROR].
Copy the data onto the hard disk before outputting it for printing.
Your RIP must be compatible with USB 2.0.
USB 2.0 repeater cable
Summary of Contents for JV5-320S
Page 6: ...iv ...
Page 63: ...2 27 About Function Menus 1 Only when dedicated sublimation transfer ink is used POST ...
Page 273: ...6 39 Function Flowchart BOOT POST POST ...
Page 275: ...6 41 Function Flowchart LOCAL mode S ...
Page 276: ...6 Operation for Functions 6 42 POST POST POST POST ...
Page 277: ...6 43 Function Flowchart LOCAL mode ...
Page 278: ...6 Operation for Functions 6 44 Function Flowchart REMOTE mode POST POST POST POST POST POST ...
Page 279: ...6 45 Function Flowchart REMOTE mode POST ...
Page 281: ...6 47 Function Flowchart FUNCTION Key POST POST POST POST POST POST POST ...
Page 283: ...6 49 Function Flowchart FUNCTION Key ...
Page 284: ...6 Operation for Functions 6 50 POST POST POST DECIDE ENTER TIMER SET FUNC POST POST ...
Page 286: ...6 Operation for Functions 6 52 POST POST POST ...
Page 287: ...6 53 Function Flowchart FUNCTION Key ...
Page 288: ...6 Operation for Functions 6 54 ...
Page 289: ...6 55 Function Flowchart FUNCTION Key CLtypeSetWithFUNCkey Yes ...
Page 290: ...6 Operation for Functions 6 56 ...
Page 291: ...6 57 Function Flowchart FUNCTION Key ...
Page 292: ...6 Operation for Functions 6 58 ...
Page 293: ...6 59 Function Flowchart FUNCTION Key ...
Page 294: ...6 Operation for Functions 6 60 ...
Page 295: ...6 61 Function Flowchart FUNCTION Key ...
Page 296: ...6 Operation for Functions 6 62 ...
Page 297: ...6 63 Function Flowchart FUNCTION Key ...
Page 298: ...6 Operation for Functions 6 64 ...
Page 299: ...6 65 Function Flowchart FUNCTION Key ...
Page 300: ...6 Operation for Functions 6 66 ...
Page 302: ...6 Operation for Functions 6 68 ...
Page 303: ...6 69 Function Flowchart FUNCTION Key ...
Page 304: ...6 Operation for Functions 6 70 ...
Page 305: ...6 71 Function Flowchart FUNCTION Key ...
Page 306: ...6 Operation for Functions 6 72 ...
Page 307: ...6 73 Function Flowchart FUNCTION Key ...
Page 308: ...6 Operation for Functions 6 74 ...
Page 309: ...6 75 Function Flowchart FUNCTION Key ...
Page 310: ...6 Operation for Functions 6 76 D201703 21 31102014 ...
Page 311: ......
Page 312: ...Printed in Japan MIMAKI ENGINEERING CO LTD FW 7 5 IT ...