© 2014 MIMAKI ENGINEERING CO.,LTD.
6.4.11
P.1
1
2
3
4
5
6
7
8
6.4.11 Drying Fan Assy.
Work procedures
1. Remove the connector.
2. Push up the stoppers at bottom of the cover, and then remove
the Assy. together with cover.
3.
Reverse the disassembly procedure for reassembly.
Turn the main power OFF when turning the power OFF.
It is very dangerous if sleep mode functions mistakenly during the operation.
Drying fan Assy x5(160 size), x4(130 size)
Connector
Push stoppers
When attaching, push down the stopper and fix the
Assy. It is not fixed only by having fitted it.
R.1.0