© 2014 MIMAKI ENGINEERING CO.,LTD.
6.2.7
P.2
6.2.7 Circulation Filter
1
2
3
4
5
6
7
8
3. Remove the Circulation filter
by
releasing the stopper.
4. Reverse the disassembly procedure for reassembly.
Work procedure of air purge in the filter after replacement.
1. Select [#ADJUST]-[FILTER REPLACE]
Press [ENTER] key.
2. Check the amount of the waste ink, and discard as required it
appropriately.
3. Perform ink refilling after air discharging.
After that, perform cleaning automatically, and then operation is
finished.
Push claw
Circulation Filter x2
If reinserting the tube, cut about 5 mm from the tube
tip before reusing it.
#
ADJUST
フィルター コウカン
[ENT]
#フィルター コウカン
カンリョウ
[ENT]
廃インクタンク確認
level:xx% (xxxL)
#フィルター コウカン
ジュウテンカイシ
[ENT]
** ジュウテン **
しばらくお待ちください
クリーニング中
Indicated that waste ink
amount is over 50%
#チョウセイ
フィルター コウカン
[ENT]
Air purge / ink refilling
Hard cleaning
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Ink-related Parts > Circulation Filter
Model
JV300-130/160
Issued 2014.05.30 Revised
F/W ver
1.00
Remark
1.0
Rev.
Summary of Contents for JV300-130 A
Page 243: ......