7.1.4 List of SYSTEM HALT
List of SYSTEM HALT (1/5)
No.
LCD
Cause
Corrective Measures
1
SYSTEM HALT (*)
10e :FROM CLEAR
F-ROM CLEAR error (F-ROM clear unable)
F-ROM is not clearable on Parameter
writing, FW down loading and Log clearing.
(fls_secclr)
1. Execute the memory check (F-ROM) of [#TEST].
2. Upload the parameter and initialize all parameters with
[#PARAMETER].
3. Replace the MAIN PCB with a new one.
(
See 3.3.1)
2
SYSTEM HALT (*)
10f : FROM WRITE
FROM WRITE error (F-ROM writing
unable)
F-ROM is not clearable on Parameter
writing, FW down loading and Log clearing.
(fls_secclr)
1. Execute the memory check (F-ROM) of [#TEST].
2. Upload the parameter and initialize all parameters with
[#PARAMETER].
3. Replace the MAIN PCB with a new one.
(
See 3.3.1)
3
SYSTEM HALT (*)
110 : PCB KEY
No Keyboard PCB
1. Check the connections between the Keyboard PCB and
the MAIN PCB and then disconnect and connect the
FFCs.
2. Replace the FFCs of the above routes.
3. Replace the Keyboard PCB with a new one.
4. Replace the MAIN PCB with a new one.
(
See 3.3.1)
4
SYSTEM HALT (*)
112 :
No CART IO PCB
1. Check the connections between the COM32IO PCB
and the CART IO PCB, and then disconnect and
connect the FFCs.
2. Replace the FFCs and the cabeles of the above routes.
3. Replace the CART IO PCB with a new one.
4. Replace the COM32IO PCB with a new one.
5
SYSTEM HALT (*)
122 : PRAM NONE
No PRAM
1. Update F/W.
2. Replace the PRAM PCB with a new one.
3. Replace the MAIN PCB with a new one.
(
See 3.3.1)
6
SYSTEM HALT (*)
123 : PRAM DATA
PRAM data error
7
SYSTEM HALT (*)
124 : PRAM ADDR
PRAM address error
8
SYSTEM HALT (*)
125 : EEPROM READ
EEPROM read trouble
CIO Register (EER:Address 74) bit6
1. Update F/W.
2. Check the connection state between SL2H PCB - Head
memory PCB.
3. Replace the Head memory PCB with a new one.
4. Check the connection state between SL2H PCB -
MAIN PCB.
5. Replace the SL2H PCB with a new one.
6. Replace the MAIN PCB with a new one.
(
See 3.3.1)
9
SYSTEM HALT (*)
126 : EEPROM WR
EEPROM write trouble
CIO Register (EER:Address 74) bit
7
10
SYSTEM HALT (*)
127 : POWER OFF
Power OFF detection error (Not to OFF)
Power OFF process is conducted in the
Power ON/OFF control without pushing
down the sub-power SW.
1. Check the connections between the Keyboard PCB
and the MAIN PCB.
2. Check the connector connection of DC Power Supply
(42V).
3. Check if there is no error on the power path from the
AC Inlet.
4. Replace the DC Power Supply(42V) with a new one.
5. Replace the Keyboard PCB with a new one.
6. Replace the MAIN PCB with a new one.
(
See 3.3.1)
11
SYSTEM HALT (*)
147 : DS-IC BUSY
DALLAS IC BUSY error
1. Check connection of the ID Contact PCB connection
cable and damage of the cable.
2. Try to use a different cartridge.
3. Replace the ID Contact PCB Assy. with a new one.
(
See 6.4.14)
4. Replace the CART IO PCB with a new one.
12
SYSTEM HALT (*)
189 : COM VOLT
COM Voltage is abnormal
1. Replace the HDC PCB with a new one.
2. Check the connections between the HDC PCB and the
Print head.
MAINTENANCE MANUAL > Troubleshooting > Details on Errors and Malfunctions > List of SYSTEM HALT
Model
JV300-130/160
Issued 2014.05.30 Revised
F/W ver
1.10
Remark