© 2014 MIMAKI ENGINEERING CO.,LTD.
4.3.9
P.4
4.3.9 Parallelism adjustment of the Tension Bar
1
2
3
4
5
6
7
8
10. Apply a second piece of tape, touching the first one.
11. Remove the tape affixing the wire to the platen cover FL.
12. Loosen the screws of the clamp base and remove the wire from
the PR shaft.
13. Feed the wire through the PR shaft on the clamp base on the left
side of the printer in the same way as Steps 1 to 4.
14. With the wire vertical, affix it to the platen cover FL using tape.
15. With the wire tense, pull the wire to the platen cover FL.
16. Confirm the position of the second piece of tape compared to
the first one.
• If the edge of the tape touches the first piece:
Complete adjustment.
• Anything else:
Perform the following adjustment.
Wire
Second tape
PR shaft
Tape
First tape
Attach the second tape without any gap to the first
tape.
Second tape
First tape
No gap in between
Wire
PR shaft
Tape
Platen cover FL
Apply tension appropriately to the wire.
First tape /
Second tape
OK
Second tape
(OK example)
Tolerance
:1 mm
First tape
NG
Second tape
(wrong case 1)
Second tape
(Wrong case 2)
First tape
Platen cover FL
Wire
OK
Wrong
①
Wrong
②
No gap
(±1 mm or less)
Overlap
There is a
gap
R.1.0