© 2014 MIMAKI ENGINEERING CO.,LTD.
7.1.4
P.4
7.1.4 List of SYSTEM HALT
1
2
3
4
5
6
7
8
42
SYSTEM HALT (*)
509 : HDC POSCNT
HDC position counter error
1. [
Execute and confirm [#TEST][SENSOR]
[Y-ORIGIN].(Confirm that the ON/OFF display is
switched by moving the carriage left and right.)
2. Execute [#TEST][CHECK ENCODER].
3. Check the assembly of Y-scale, and confirm that there
is neither dirt nor scratch.
4. Check in manual if the Head Assy. (carriage) moves
left and right smoothly.
5. Check the connector connection of Y-origin Sensor
and Linear Encoder.
6. Replace the Y-origin Sensor or Linear Encoder with a
new one.
7. Check the assembly and connector connection of Y-
axis Motor.
8. Replace the Y-axis Motor with a new one.
(
See 6.3.2)
9. Replace the HDC PCB with a new one.
10. Replace the MAIN PCB with a new one.
(
See 3.3.1)
43
SYSTEM HALT (*)
801 : (C)OPCODE
System error
(CPU exception: OP code error)
11. Check the peripheral temperature of MAIN PCB, and
then check if the error is caused by the thermo runaway
of CPU.
12. Make sure that there is no device generating strong
radio wave in the vicinity.
13. Replace the MAIN PCB with a new one.
(
See 3.3.1)
14. Replace the DC Power Supply(5V) with a new one.
(
See 6.4.1)
44
SYSTEM HALT (*)
802 : (C)SLOT
System error
(CPU exception: Slot instruction error)
45
SYSTEM HALT (*)
803 : (C)CPU ADDR
System error
(CPU exception: CPU address error)
46
SYSTEM HALT (*)
804 : (C)DMA ADDR
System error
(CPU exception: DMA address error)
47
SYSTEM HALT (*)
806 : FW/SIO bit
FW error
(Serial control F/W error (bit control))
The area where the registration data shall be
cashed cannot be found. (It is not
registered.)
The errors of 800s below are “FW error”.
1. Update F/W.
2. Check and clear the parameter.
3. Replace the MAIN PCB with a new one.
(
See 3.3.1)
48
SYSTEM HALT (*)
807 : FW/SIO wbsy
FW error
(Serial control F/W error (WR BUSY))
49
SYSTEM HALT (*)
808 : FW/STP-MTR
FW error
(Step Motor stop waiting)
50
SYSTEM HALT (*)
809 : FW/XY param
FW error
(XY-axis Motor resolution conversion
parameter error)
51
SYSTEM HALT (*)
80a : FW/Y RANGE
FW error
(Y movable range error)
52
SYSTEM HALT (*)
80b : FW/ctrltsk
FW error
(Motor control task error)
53
SYSTEM HALT (*)
80c : FW/PUMP W
FW error
(Suction Pump stop waiting time over at
capping)
54
SYSTEM HALT (*)
80d : FW/SERVO IT
FW error
(Servo interruption error)
55
SYSTEM HALT (*)
80e : FW/FROM prm
FW error
(FROM PARAM error (F/W BUG))
56
SYSTEM HALT (*)
80f : FW/SIO vch
FW error
(Virtual serial CH setting error)
List of SYSTEM HALT (4/5)
No.
LCD
Cause
Corrective Measures