© 2014 MIMAKI ENGINEERING CO.,LTD.
6.4.6
P.1
1
2
3
4
5
6
7
8
6.4.6 CART IO PCB Assy
Work procedures
1. Remove the
Cartridge cover
.
2. Remove the
Cartridge IO PCB BKT
(screw x4).
3. Remove the
CART IO PCB Assy
(screw x3).
4. Reverse the disassembly procedure for reassembly.
Turn the main power OFF when turning the power OFF.
It is very dangerous if sleep mode functions mistakenly during the operation.
CARTO IO PCB Assy
Cartridge IO PCB BKT
Screw x4
CART IO PCB
Assy
Screw x3
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Electrical Parts > CART IO PCB Assy
Model
JV300-130/160
Issued 2014.05.30 Revised
F/W ver
1.00
Remark
1.0
Rev.
Summary of Contents for JV300-130 A
Page 243: ......
Page 244: ...D500946 10 30052014 MIMAKI ENGINEERING CO LTD 2014 KF FW 1 1 ...