1.3.5 Supply Valve Control
Cartridge switching operation
Timing to open/close the supply valve
The supply valves are usually closed and opened only when ink supply is required.
Timing to open/close the supply valves is shown below:
Event
For the 4-color ink set
Except for the
4-color ink set
Cartridge 1
valve
Cartridge 2
valve
Cartridge 1
valve
1
Online supply start
Both cartridges free from problems
Cartridge 1 is the control cartridge.
OPEN
CLOSE
OPEN
2
Cartridge 1
Cartridge near end
No change
No change
No change
3
Cartridge 1
Cartridge ink end
Cartridge 2 is the control cartridge.
CLOSE
OPEN
CLOSE
4
Cartridge 2
Cartridge near end
No change
No change
5
Cartridge 1
Removed for replacement
No change
No change
CLOSE
6
Cartridge 1
A normal cartridge has been set
CLOSE
OPEN
OPEN
7
Cartridge 2
Cartridge ink end
Cartridge 1 is the control cartridge.
OPEN
CLOSE
8
Online printing has been completed
All valves closed
CLOSE
CLOSE
CLOSE
Timing to open/close the supply valves
Instruction to open/
close the supply valve
Flushing
Before execution
OPEN
After execution
CLOSE
Cleaning or filling
Before execution
OPEN
After execution
CLOSE
Head wash
Before execution
OPEN
After execution
CLOSE
Before printing operation
OPEN
Before capping operation
CLOSE
When changing the supply cartridge during ink supply
OPEN/CLOSE
At the occurrence of an system error
CLOSE
At power-off
CLOSE