© 2014 MIMAKI ENGINEERING CO.,LTD.
7.1.2
P.7
7.1.2 List of Error Messages
1
2
3
4
5
6
7
8
72
ERROR 902
DATA REMAIN
Drawing data is remaining.
(Carry out the followings if the error still occurs when
data is cleared.)
1. Check errors in the parameter.
2. Remove USB cable from the printer and execute data
clear. -> If solved, it is a problem on USB cable or PC.
3. Replace the USB Cable with a new one.
4. Replace the MAIN PCB with a new one.
(Refer to
3.3.1)
73
ERROR 909
PARAMETER VERSION
Parameter version which is downloaded is
different from FW version.
1. Check the FW version of the parameter which is
downloaded.
74
ERROR 90d
NO HEAD SELECT
Loaded number of the head is assumed
zero.
1. Check the setting of loading number of the head in the
parameter.
(System parameter No.41 “HEAD NO”=2)
75
ERROR 90f
PRINT AREA SHORT
Lacking printing area in printing the built-
in pattern.
1. Move the Y origin.
2. Replace the media.
76
ERROR 04
PARAM ROM
Access Error of the PARAMETER ROM
1.The state that cannot access
“FROM” on the MAIN PCB.
2.Parameter data is abnormal.
1. Initialize parameter data.
2. Replace the MAIN PCB with a new one.
(Refer to
3.3.1)
List of Error Messages (7/7)
No.
LCD
Cause
List of Countermeasures
R.1.0
MAINTENANCE MANUAL > Troubleshooting > Details on Errors and Malfunctions > List of Error Messages
Model
JV300-130/160
Issued 2014.05.30 Revised
F/W ver
1.10
Remark
1.0
Rev.
Summary of Contents for JV300-130 A
Page 243: ......
Page 244: ...D500946 10 30052014 MIMAKI ENGINEERING CO LTD 2014 KF FW 1 1 ...