© 2014 MIMAKI ENGINEERING CO.,LTD.
6.4.12
P.1
1
2
3
4
5
6
7
8
6.4.12 240W42V Power Supply Assy.
Work procedures
1. Turn off the main power supply and remove the power plug
from the main body.
2. Remove the
Electrical box cover
and
Power supply cover
.
3. Disconnect all
connectors
on PCB.
4. Remove the screws and then remove the
240W42V power sup-
ply Assy
.
5. Reverse the disassembly procedure for reassembly.
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15 minutes
before restarting the operation. It is very dangerous if sleep mode functions mistakenly during the
operation.
Moreover, the PCB may be damaged in case electric charge still remains inside.
Also, there is a possibility of electric shock because of high power voltage applied to the high-pressure
part of PCBs. Take care to avoid contact with it.
240W42V Power supply Assy
240W42V Power supply Assy.
Power supply cover
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Electrical Parts > 240W42V Power Supply Assy.
Model
JV300-130/160
Issued 2014.05.30 Revised
F/W ver
1.00
Remark
1.0