98
SPN # FMI # Cummins
Fault #
Lamp Color Reason For Fault
Effect If Fault Is Active
Course Of Action
620
3
227
Yellow
High Voltage Detected On
The Ecm Voltage Supply
Line To Some Sensors
Engine Will Run Derated.
No Engine Protection For
Oil Pressure Or Coolant
Level.
Call Cummins
Service
620
4
352
Yellow
Low Voltage Detected On
The Ecm Voltage Supply
Line To Some Sensors
Engine Is Derated To No
Air Setting
Call Cummins
Service
623
3
255
Yellow
Engine Fuel Shutoff
Valve Drive Circuit - Volt-
age Above Normal Or
Shorted To High Source.
Open Circuit Or Short To
Voltage Source Detected
At Fuel Shutoff Valve
Circuit.
None On Performance.
Fuel Shutoff Valve Stays
On.
Call Cummins
Service
627
2
434
Yellow
Supply Voltage To The
Ecm Fell Below +6.2 Vdc
For A Fraction Of A Sec-
ond Or The Ecm Was Not
Allowed To Power Down
Correctly For 30 Seconds
Between Key Off And
Key On
Possible No Noticeable
Performance Effects Or
Engine Dying Or Hard
Starting.
Check For Low
Voltage During
Cranking. Wait 30
Seconds Between
Key Off And Turning
Key Back On. Call
Cummins Service
629
12
111
Red
Error Internal To The Ecm
Related To The Memory
Hardware Failures Or
Internal Ecm Voltage
Supply Circuits
Engine Will Not Start
Call Cummins
Service
629
12
343
Yellow
Internal Ecm Error
Possibly None On Perfor-
mance, Or Severe Derate
Check Battery And
All Ground Connec-
tions. Call Cummins
Service.
630
2
341
Yellow
Severe Loss Of Data
From The Ecm
Possible No Noticeable
Performance Effects, Or
Engine Dying, Or Difficul-
ty In Starting The Engine.
Fault Information, Trip
Information And Mainte-
nance Monitor Data Can
Be Inaccurate
Check Battery Con-
nections, Check 15
Amp Fuses, Check
Oem Harness Con-
nections. Call Cum-
mins Service.
632
4
254
Red
Less Than 6 Vdc Detect-
ed At Fuel Shutoff Circuit
Or An Excessive Current
Draw From The Ecm Or
A Faulty Ecm Output
Circuit.
The Ecm Turns Off The
Fuel Shutoff Supply Volt-
age. The Engine Will Shut
Down.
Call Cummins
Service
632
7
259
Yellow
The Ecm Detected That
The Fuel Shutoff Valve Is
Stuck Open Mechanically
Or Leaking
Engine Will Have A
Torque Derate
Call Cummins
Service
633
5
378
Yellow
Low Current Or Open
Circuit Detected At Front
Fueling Actuator Circuit
Engine Will Run Using
Only The 3 Rear Cylin-
ders
Call Cummins
Service
Summary of Contents for AG-BAG Professional LX1214
Page 20: ...14 Safety Sign and Decal Locations...
Page 21: ...15 Safety Sign and Decal Locations continued...
Page 128: ...122 Maintenance Record Date Service Performed...
Page 129: ...123 Date Service Performed...
Page 130: ...124 Date Service Performed...
Page 158: ...2014 by Miller St Nazianz Inc...