63
TONS
TREATED
PER TANK
250
500
750
APPLICATION
RATE (GAL/
TON)
0.232
0.116
0.077
BAGGING
RATE (TONS/
MINUTE)
4
6
8
10
4
6
8
10
4
6
8
10
SPRAY
RATE
(GPM)
0.928
1.392
1.856
2.32
0.464
0.696
0.928
1.16
0.309
0.462
0.616
0.77
RATE PER
NOZZLE
(GPM)
0.232
0.348
0.464
0.580
0.116
0.174
0.232
0.290
0.077
0.116
0.154
0.193
SPRAY TIP
REQUIRED
XRC110025
XRC11003
XRC11004
XRC11005
XRC11005
XR11006
XR11006
XR11008
XR110015
XRC11002
XRC11002
XRC110025
XRC110025
XRC11003
XRC11003
XRC11004
XR11001
XR110015
XRC11002
XRC11002
XRC110025
XRC110025
XRC11003
AG BAG PART
NO.
07.08287
07.08288
07.08289
07.08290
07.08290
07.17242
07.17242
07.17269
07.17735
07.09647
07.09647
07.08287
07.08287
07.08288
07.08288
07.08289
07.17734
07.17735
07.09647
07.09647
07.08287
07.08287
07.08288
(PSI)
33
24
30
20
34
24
38
21
24
15
30
19
34
24
38
22
25
24
15
23
15
23
17
Spray Tip Selection & Pressure Set-
tings Guide
Cleaning The Inoculant System
The inoculant system should be drained and
flushed with clean water daily. This will keep the
inoculant in the system from clogging the pump,
valve or spray tips. Thoroughly clean before
storing. See “Storage”.
Summary of Contents for AG-BAG Professional LX1214
Page 20: ...14 Safety Sign and Decal Locations...
Page 21: ...15 Safety Sign and Decal Locations continued...
Page 128: ...122 Maintenance Record Date Service Performed...
Page 129: ...123 Date Service Performed...
Page 130: ...124 Date Service Performed...
Page 158: ...2014 by Miller St Nazianz Inc...