Technical Information
5
DGC 6xxx
4.2
Heat-Flow Fan (2M2-1) Removal ........................................................................ 81
4.3
Feed Pump (M7) Removal .................................................................................. 82
4.4
Fascia Panel Position Switch (S60) Removal ..................................................... 83
4.5
Water Container Switch (B3-17, B3-18, B3-19) Removal ................................... 83
4.6
Drain Pump Reed Switch (B1-2) Removal .......................................................... 84
4.7
Lighting Electronic (N1/10) Removal .................................................................. 84
4.8
Power Electronic (N1-1) Removal ....................................................................... 85
4.9
Inlet Valve Removal ............................................................................................ 86
4.10
Air Duct Removal ................................................................................................ 87
4.11
Roast Probe Electronic (N1-6) Removal ............................................................. 89
4.12
Wireless Roast Probe Test ................................................................................. 90
060
Control Panel ............................................................................................ 92
2
Function ................................................................................................................. 92
2.1
Optical Interface .................................................................................................. 92
2.2
M-Touch Display (Model-Dependent) ................................................................. 92
2.3
Loudspeaker ....................................................................................................... 93
2.4
Operating Modes ................................................................................................ 94
2.4.1
Heater-Element Configurations ........................................................................ 94
2.4.2
Overview .......................................................................................................... 95
3
Fault Repair ............................................................................................................ 96
3.1
Fault Code F05 - Oven Pt1000 Temperature Sensor Short- Circuited ............... 96
3.2
Fault Code F06 - Oven Pt1000 Temperature Sensor Open- Circuited ............... 96
3.3
Fault Code F07 ................................................................................................... 97
3.4
Fault Code F10 - Steam Generator Water Intake Fault ...................................... 97
3.5
Fault Code F11 - Steam Generator Drainage Fault ............................................ 99
3.6
Fault Code F20 – Heating Fault ........................................................................ 100
3.7
Fault Code F44 - Control Electronic/Power Electronic Interface Fault ............. 100
3.8
Fault Code F54 – Roast Probe Short-Circuited ................................................ 100
3.9
Fault Code F55 - Safety Cut-Out ...................................................................... 100
3.10
Fault Code F60 - Power Electronic Temperature Limit Exceeded .................... 101
3.11
Fault Code F74 – Drain Valve Fault .................................................................. 101
3.12
Fault Code F94 - Plumbed-Water Connection Water Intake Fault .................... 101
3.13
Fault Code F190 - Plumbed-Water Connection Valve Defective ...................... 101
3.14
Fault Code F191 - Heat-Flow Pt1000 Temperature Sensor Short- Circuited .... 101
3.15
Fault Code F192 - Heat-Flow Pt1000 Temperature Sensor Open- Circuited ... 102
3.16
Fault Code F193 - Bottom Heat Pt1000 Temperature Sensor Short- Circuited 102
3.17
Fault Code F194 - Bottom Heat Pt1000 Temperature Sensor Open- Circuited 102
3.18
Fault Code F195 – Roast Probe Electronic Communication Fault .................... 102
3.19
Fault Code F196 - Pump Sump Fault ............................................................... 103
3.20
Fault Code F197 – Cooling-Air Pt1000 Short Circuit ........................................ 104
3.21
Fault Code F198 – Cooling-Air Pt1000 Open Circuit ........................................ 104
3.22
Fault Code F235 – Control/Power Electronic Communication Fault ................. 105
3.23
Fault Code F241 - Touchpad Communication Fault ......................................... 105
3.24
Fault Code F242 - Touchscreen Communication Fault .................................... 105
3.25
Update Was Not Successful ............................................................................. 105
3.26
Delay Start Cannot Be Selected ....................................................................... 106
3.27
End Time Not Displayed ................................................................................... 106
3.28
Appliance Must Be Descaled Frequently .......................................................... 106
Summary of Contents for DGC 6 Series
Page 1: ...TECHNICAL INFORMATION DGC 6xxx Combi Steam Ovens 2018 Miele USA ...
Page 15: ...Technical Information 15 DGC 6xxx 010 Casing ...
Page 23: ...Technical Information 23 DGC 6xxx 020 Door ...
Page 27: ...Technical Information 27 DGC 6xxx 030 Cavity ...
Page 43: ...Technical Information 43 DGC 6xxx 035 Steam Generator Convection Fan ...
Page 57: ...Technical Information 57 DGC 6xxx Figure 035 14 Terminal Block ...
Page 58: ...Technical Information 58 DGC 6xxx 040 Water Container Drive ...
Page 68: ...Technical Information 68 DGC 6xxx 045 Air Duct Power Electronic ...