Install a new drain valve. See Section 035-4.6.
Cause:
Drain hose under the steam generator has flattened and stuck together.
Remedy:
Install a new drain hose.
3.5
Fault Code F11 - Steam Generator Drainage Fault
Symptom:
Fill-level electrode (E1/2) constantly provides a fill-level signal.
Cause:
Drain hoses blocked.
Remedy:
Clean the drain hoses.
Cause:
Feed pump (M7) operates constantly.
Remedy:
Install a new feed pump. See Section 045-4.3.
Note:
The feed pump is installed with a blocking diode. This can lead to a faulty
resistance measurement being made. In order to ensure a correct
measurement, always measure the resistance of the feed pump twice with
the polarity reversed.
Cause:
Fill-level electrode (E1/2) defective.
Remedy:
Replace the steam generator. See Section 035-4.4.
Cause:
Drain valve (M29) permanently closed.
Remedy:
Install a new drain valve. See Section 035-4.6.
Cause:
The steam generator is clogged with limescale.
Descaling is not strong enough. Limescale residue remains in the steam
generator and clogs drainage.
Series modification:
Modified operating instructions. The descaling process now requires two
descale tablets.
Remedy:
Notify the customer that the descaling process now requires two descale
tablets.
Summary of Contents for DGC 6 Series
Page 1: ...TECHNICAL INFORMATION DGC 6xxx Combi Steam Ovens 2018 Miele USA ...
Page 15: ...Technical Information 15 DGC 6xxx 010 Casing ...
Page 23: ...Technical Information 23 DGC 6xxx 020 Door ...
Page 27: ...Technical Information 27 DGC 6xxx 030 Cavity ...
Page 43: ...Technical Information 43 DGC 6xxx 035 Steam Generator Convection Fan ...
Page 57: ...Technical Information 57 DGC 6xxx Figure 035 14 Terminal Block ...
Page 58: ...Technical Information 58 DGC 6xxx 040 Water Container Drive ...
Page 68: ...Technical Information 68 DGC 6xxx 045 Air Duct Power Electronic ...