Technical Information
105
DGC 6xxx
3.22
Fault Code F235 – Control/Power Electronic Communication Fault
Cause:
MBUS hardware on control or power electronic defective.
Remedy:
Replace control or power electronic. See Section 060-4.4 or Section 045-4.8.
Cause:
Short circuit in wiring harness.
Remedy:
Replace the wiring harness between the control and power electronics.
Cause:
EMV interference.
Remedy:
Locate the source of EMV interference and remove it, if possible.
3.23
Fault Code F241 - Touchpad Communication Fault
Cause:
Communication to touchpad controller on control electronic is defective or
open-circuited.
Remedy:
Replace control electronic. See Section 060-4.4.
3.24
Fault Code F242 - Touchscreen Communication Fault
Cause:
Communication to touchscreen controller on control electronic is defective or
open-circuited.
Remedy:
Replace control electronic. See Section 060-4.4.
3.25
Update Was Not Successful
Symptom:
During an update, the following message occurs: "Firmware update fault! A
fault occurred during the update. Repeat the update process or the control
will have to be replaced! Repeat the update process?"
Cause:
Too many power losses during data transfer.
Remedy:
Update directly at the control electronic using a fiberoptic cable.
Note:
The MDU must remain in “message” status; the update must not be
canceled with "No".
1. Disconnect the appliance from the power supply.
Summary of Contents for DGC 6 Series
Page 1: ...TECHNICAL INFORMATION DGC 6xxx Combi Steam Ovens 2018 Miele USA ...
Page 15: ...Technical Information 15 DGC 6xxx 010 Casing ...
Page 23: ...Technical Information 23 DGC 6xxx 020 Door ...
Page 27: ...Technical Information 27 DGC 6xxx 030 Cavity ...
Page 43: ...Technical Information 43 DGC 6xxx 035 Steam Generator Convection Fan ...
Page 57: ...Technical Information 57 DGC 6xxx Figure 035 14 Terminal Block ...
Page 58: ...Technical Information 58 DGC 6xxx 040 Water Container Drive ...
Page 68: ...Technical Information 68 DGC 6xxx 045 Air Duct Power Electronic ...