Technical Information
39
DGC 6xxx
4.9
Heat-Flow Temperature Sensor (2R30-10) Replacement
1. Remove the appliance from its housing unit; see Section 010-4.1.
2. Disconnect the appliance from the power supply.
3. Remove the lid; see Section 010-4.2.
4. Remove the right side panel; see Section 010-4.3.
5. Remove the rear/left side panel, if necessary; see Section 010-4.4.
6. Pull off the black hose between the cable duct and the heat-flow fan
housing (Figure 030-13, Item 3).
7. Remove the cable duct; see Section 010-4.6.
8. Disconnect the two red wires from the cooling-air temperature sensor
(Figure 030-13, Item 1).
9. Remove the two T20 screws securing the heat-flow fan housing (see
arrows, Figure 030-14); take out the housing.
Figure 030-14:
Heat-Flow Fan Housing Screws
10. Release the retaining pins securing the heat-flow temperature sensor
housing to the metal air shield (see arrows, Figure 030-15); remove the
temperature sensor housing from the air shield.
Summary of Contents for DGC 6 Series
Page 1: ...TECHNICAL INFORMATION DGC 6xxx Combi Steam Ovens 2018 Miele USA ...
Page 15: ...Technical Information 15 DGC 6xxx 010 Casing ...
Page 23: ...Technical Information 23 DGC 6xxx 020 Door ...
Page 27: ...Technical Information 27 DGC 6xxx 030 Cavity ...
Page 43: ...Technical Information 43 DGC 6xxx 035 Steam Generator Convection Fan ...
Page 57: ...Technical Information 57 DGC 6xxx Figure 035 14 Terminal Block ...
Page 58: ...Technical Information 58 DGC 6xxx 040 Water Container Drive ...
Page 68: ...Technical Information 68 DGC 6xxx 045 Air Duct Power Electronic ...