Technical Information
49
DGC 6xxx
rapidly expands as it changes state to steam when it comes into contact with
the hot water already in the steam generator. The drip shield vibrates and
causes these noises.
Series modification:
Modified drip shield in steam generator. This new steam generator has been
incorporated since 13 July 2011, starting with machine no. 111011512.
Remedy:
Install the new steam generator (refer to the parts CD for current part
numbers). See Section 035-4.4.
3.2
Residual Water in Cavity
Symptom:
Residual water remains in the cavity. This is especially noticeable with the
automatic rinsing cycle. The drain pump operates for only 20 seconds and
then switches off even though water remains in the pump sump.
Cause:
Drain pump reed switch defective.
Remedy:
Replace the drain pump reed switch (refer to the parts CD for current part
numbers). See Section 045-4.6.
3.3 Hose
Kinked
Symptom:
A hose from the steam generator output to the cavity is kinked.
Cause:
Due to heating, the hose which has been laid too tightly has kinked.
Series modification:
Modification of hose positioning.
Remedy:
Summary of Contents for DGC 6 Series
Page 1: ...TECHNICAL INFORMATION DGC 6xxx Combi Steam Ovens 2018 Miele USA ...
Page 15: ...Technical Information 15 DGC 6xxx 010 Casing ...
Page 23: ...Technical Information 23 DGC 6xxx 020 Door ...
Page 27: ...Technical Information 27 DGC 6xxx 030 Cavity ...
Page 43: ...Technical Information 43 DGC 6xxx 035 Steam Generator Convection Fan ...
Page 57: ...Technical Information 57 DGC 6xxx Figure 035 14 Terminal Block ...
Page 58: ...Technical Information 58 DGC 6xxx 040 Water Container Drive ...
Page 68: ...Technical Information 68 DGC 6xxx 045 Air Duct Power Electronic ...