Technical Information
100
DGC 6xxx
Note:
The customer can download or request a new set of operating instructions.
Cause:
Power electronic (N1-1) defective.
Remedy:
Install a new power electronic. See Section 045-4.8.
3.6
Fault Code F20 – Heating Fault
Cause:
Fill-level electrode E1-2 receiving constant fill-level signal. Steam generator
heating defective.
Remedy:
Replace steam generator. See Section 035-4.4.
3.7
Fault Code F44 - Control Electronic/Power Electronic Interface
Fault
Cause:
Faulty communication between the control electronic (N1-2) and power
electronic (N1-1).
Remedy:
1. Check the plugs for correct seating and contact.
2. Check the wiring harness.
3. Replace the wiring harness with plugs, if necessary.
Cause:
Control electronic (N1-2) defective.
Remedy:
Install a new control electronic. See Section 060-4.3.
Cause:
Power electronic (N1-1) defective.
Remedy:
Install a new power electronic. See Section 045-4.8.
3.8
Fault Code F54 – Roast Probe Short-Circuited
Cause:
Sensor is short-circuited in its connection to ET 7440 or ELP 7440 electronic
Remedy:
1. Replace roast probe or its wiring.
2. Replace roast probe electronic. See Section 045-4.11.
3. Install a new power electronic. See Section 045-4.8.
3.9
Fault Code F55 - Safety Cut-Out
Symptom:
Summary of Contents for DGC 6 Series
Page 1: ...TECHNICAL INFORMATION DGC 6xxx Combi Steam Ovens 2018 Miele USA ...
Page 15: ...Technical Information 15 DGC 6xxx 010 Casing ...
Page 23: ...Technical Information 23 DGC 6xxx 020 Door ...
Page 27: ...Technical Information 27 DGC 6xxx 030 Cavity ...
Page 43: ...Technical Information 43 DGC 6xxx 035 Steam Generator Convection Fan ...
Page 57: ...Technical Information 57 DGC 6xxx Figure 035 14 Terminal Block ...
Page 58: ...Technical Information 58 DGC 6xxx 040 Water Container Drive ...
Page 68: ...Technical Information 68 DGC 6xxx 045 Air Duct Power Electronic ...