CHAPTER 4– Programming Control Panel
include all areas of the first floor, or for "logical" reasons, "Doors and Windows" area could
include all areas that protect entry points in a home.
Parameter Options
Description
Description
12 characters
Area Description. Description appears during configuration, either by keyboard then by
SynergyPro SW, in every log, and in SMS messages relative to Area
Type
Internal
When there is at least one Area of Type Internal Armed, Delayed Zones are valued by the
Control Unit with the configured delay.
Perimetric
When there are only areas of Type Perimetric Armed ones and Delayed Zones are valued by the
Control Unit with a delay of 0 (zero), that is theyare valued as Snapshots.
Exit Time
(0...300)
Time of output from the area, after the expiration of output time Control Unit begins to evaluate
the state of the Zones for the generation of eventual alarms
Patrol Time
(0…600)
Patrol Time, duration within which it must be completed the patrol. At the end of patrol time the
areas disengaged from patrol (code or key) are immediately reinstated
Timer
Parameter Options
Description
Enabled
Yes
Timer Enabled
NO
Timer Disabled
Description
12 Characters
Description of the area. The description appears in the configuration, either by keypad and SynergyPro SW,
in all logs, SMS messages, relative to the Timer
Delayable
Yes
Timer to which you can apply a delay (see 4.2.1)
NO
Timer to which you can’t apply a delay (see 4.2.1)
Warning Time
(1...30)
Warning time (min.) displayed on keyboards in order to inform the user about timer enabling. During this time
the user can delay the Timer
Monday
(--:--...24:00)
-- : -- Start of Monday time band
-- : -- end of Monday time band
To switch selection between
fields "Start Time band" and
"End Time band" use the
special "FN" key and the
arrow keys to change value of
selected field
Tuesday
(--:--...24:00)
-- : -- Start of Tuesday time band
-- : -- end of Tuesday time band
Wednesday
(--:--...24:00)
-- : -- Start of Wednesday time band
-- : -- end of Wednesday time band
Thursday
(--:--...24:00)
-- : -- Start of Tursday time band
-- : -- end of Tursday time band
Friday
(--:--...24:00)
-- : -- Start of Friday time band
-- : -- end of Friday time band
Saturday
(--:--...24:00)
-- : -- Start of Saturday time band
-- : -- end of Saturday time band
Sunday
(--:--...24:00)
-- : -- Start of Sunday time band
-- : -- end of Sunday time band
Keyboards
Parameter
Options
Description
Enable
Yes
Enabled Keyboard
NO
Disabled Keyboard
NOTE: when a keyboard is disabled, you can’t manage anymore keyboards informations
Description
12 characters
Keyboard Description. Description appears during configuration, either by keyboard then by
SynergyPro SW, in every log, and in SMS messages relative to keyboard
Areas
(Area1...Area12)
Configuring Areas to which keyboard belong
Macro F1~F4
ID Macro
(NoConfig,Macro1...Macro36) Selecting Macro to run by pressing F1~F4 keyboards keys
Auth Macro
(No one, Ok key, Code Insert) Confirmation Type for running macros assigned to F1 ~ F4 keys on the keyboard
Macro Reader 1~4
(NoConfig,Macro1..Macro36)
Selecting macros to run as F1~F4 macros of built in reader
OK
Install Menu
8)Timer
Timer
Timer 1
OK
Timer 1
Enabled
OK
Install Menu
9)Keyboards
Keyboards
Keyboard 1
OK
Keyboard 1
Enable