Installer Manual
Microvideo srl
www.microvideo.eu
41
CHAPTER 4– Programming Control Panel
The following table shows all parameters and the behavior system depending on the type
of configuration
Parameter
Option
Description
Language
Italian
Italian menus on keypads
English
English menus on keypads
Enable LedInfo
Yes
Alla keyboards send LED informations
NO
Keyboard LEDs all off, in every case of event in the plant
Segn.Led Lettore
Always Off
Proximity Readers Led always off
System Status
Proximity Readers Led Indicate the status of the system. Red LED On: System: armed.
Green Led: System: Unarmed
Flashing
Proximity Readers Led flashing for System functioning
MaxNumCalls
1..11
Number of call attempts after which unanswered calls the next number in the phonebook
MaxNumRepMsg
1,,,5
Repeats of Vocal Message of Module GSM in a Vocal call
SMS MsgDescrip
50 Caratteri
Plant description at the beginning of each SMS message sent by the GSM / GPRS
StopTel1Ans
SI
The queue of the calls will stop as soon as one of them is successful
NO
All calls are made in succession independently of whether they were successful or not
Confirm Tel
Yes
An outgoing call is considered successful when the user presses any key to answer
NO
An outgoing call is considered successful when the user answers
OnlyPhonebook
Yes
GSM module accepts incoming calls ONLY from phone numbers that in the phone book
NO
GSM module accepts incoming calls ONLY from every phone number
MinCredit
(1..255)
Minimum limit of residual credit on the SIM after which GSM module starts to send
messages to the first number in the Phonebook
SMS Deviation
NumTel1
NumTel15
Telephone Number on which are deflected SMS received by the GSM module from
numbers not in your address book
SMS Service
NumTel1
NumTel15
Phone number on which monthly messages of proper functioning of GSM module arrive
Sim Duration
Duration (in years) of validity of the SIM
Sim Data recharge
Date of Last Charge (DDMMYYYY)
Confirm SMS
Command
No one
GSM module does NO warning confirmation of commands received by SMS
SMS
GSM module replies with a confirmation SMS for recepting command
RING
GSM module replies with a confirmation phone call for recepting command
VocMsgOrd GSM
Playing order of 3 warning voice messages when a call is made
Voice Menu
NO
Vocal Menu of Keyboard Disabled
Yes
Vocal Menu of Keyboard Enabled
PasswordSize
4char
4 characters
5char
5 characters
6char
6 characters
TimeoutLogout
0..300
Time (sec) of automatic logout of the keyboards when a user does not make actions
MaxErrInsCode
NoConfig
0..5
Max Number of errors that the user has available to enter the code, before the keyboard is
locked for the time shown in the field: TimeErrInsCod
TimeErrInsCode
0..600
Time (sec.) in which the keyboard will remain locked after the limit of errors of input code is
reached by a user. Limit indicated in the field MaxErrInsCode,
MaxRitTimer
0..180
Time (min) of maximum delay that can be applied to a timer by a user to delay his execution
Daylight Saving
Time
NO
The automatic switching from summer to winter and vice versa is disabled
Yes
The automatic switching from summer to winter and vice versa is enabled
220NetAllDelay
0..65000
Time (min) delay alarm failure of Electrical Network, if after the delay time the network has
not resumed the alarm is generated
Negligence All.
0..255
Time (min) control to change of Zone System Disarmed. If, for system off, there is no
change in the status of Zone for the time indicated by the variable, then will be generated
an Event of negligence (see Special Events)
All.CheckZone
0..255
If the system is disarmed, there is no change in the Zone for the time (min) indicated by this
variable will be generated an Event of CheckUp Zone (see Programmable Events)
SatExc/Fail
NO
Reporting of Diagnostic Enabled
Yes
Reporting of Diagnostic Disable
RF supervision
0
Diagnosing Radio modules Disabled
4..20
Time (hours) after which Tamper alarm is generated if Radio module does not communicate
with the Control Unit
Forced Arming
No
Inserting System only with Zone at rest
Yes
Inserting System even with zones (bypassing type) in alarm
SatSignalFail
AlwaysActive
1..128
Indicates the maximum number of diagnostic messages that can be sent during an insert.
When reaching the maximum limit of reporting, the following ones will no longer be sent but
every one will be saved in the logs.
Summary of Contents for Synergy SY800