CHAPTER 3 – Installing
CHAPTER 3 – Installing
Installing Control Panel
To install the panel choose an hardly accessible place and not in sight. Drill holes on the
wall to fix the metal box according to the arrangement of holes (ref A).
A
Fixing holes on the wall
B
Fixing holes in the plate moduleholders
C
Opening for Tearproof Tamper of Control PAnel
D
Wiring openings
E
Hole for fixing the power terminal of the power grid
F
Support ribs for power adapter
G
Mounting lid holes
Secure control unit by anchors (at least 6 mm), making sure that wiring go through the
openings (ref. D) cable glands of the box.
Connect the power supply in the
appropriate terminal block, making sure that
the fuse of the terminal block is NOT
inserted
Verify that the tamper placed behind the
corner card holder is properly seated
Connection of Voice Module (Mod. SY-900)
The Voice Module must be plugged into the Central and allows modules Keyboard SY-820
and SY-860 GSM playback of voice messages.
Iinstallation:
1. Remove power from the Central, disconnecting the backup battery and mains power
Installazione:
2. Carefully insert the Voice module on connector of Control Panel card