Installer Manual
Microvideo srl
www.microvideo.eu
50
CHAPTER 4– Programming Control Panel
Actions
Parameter
Options
Description
Description
12 characters
Action description. Description appears during configuration, either by keyboard then by
SynergyPro SW, in every log, and in SMS messages relative to action
Type
NoConfig
Action not Configured
Output active
Inverts Default Satus of Output
Output Disabled
Output Back to Default Status
Keyboard Buzzer
Keyboard Buzzer Active
Send SMS
Sends SMS
Vocal Call
Sends a vocal call
TLV Message
Sends a Call to TLV
Alarms stop
All Outputs back to Default Status
Phone Calls Erase
Stops Actual calls and deletes Call Queue
AlarmMem Erase
All keyboards Leds, indicating Alarm memory, OFF
Area Arm
Area ared
Area Disarm
Area disarmed
DVR WALL ON
Sends PowerON command to WALL module
DVR WALL OFF
Sends PowerOFF command to WALL module
Fog machine shot active
Sends Shot command to FOG module
Element ID
(All elements,
NoConfig,Element1..Element64)
Element to which Action Type refers
Activat.Time
(0...600)
Time (sec.) of Action executing
Activat.Cycles
(0...20)
Action Executing Cycles
Delay Time
(0...600)
Delay Time (secondi) of executing action
Events
Events are messages triggered when "something" happens in the system. Each event can
be associated with an initial macro, namely a macro that is executed when the event
occurs, and a final macro that runs when you restore the conditions before the event.
For example, if we consider the event "No 220 network", the initial macro is executed
when there is a lack of power supply, while the final macro (reset) is performed when the
line voltage returns to be correct.
the events
Programmable Events
Parameter Options
Description
Type
No Config.
Not configured event
Zone Alarm
Event on Zone Alarm/rest
AreaStatusChange
Event on Area Armed/Disarmed
TimerStatusChange
Event on Start/End Timer Bands
Code Inser.
Event on valid Login Code
Key Touch on
Event on Valid authentication key
Area Alarm
Event on Area Alarm/Rest
Zone diagnostics
Event on Recovery after Tamper or recovery after Fault of the Zone
Alarm of Zone Checkup
Event on Alarm/Restore Zone Checkup: In a zone a checkup zones occurs when for a specific time (given
in general parameters), in NOT armed Status, NEVER changes its Status
Element
(All elements,
NoConfig,Elemento1..Elemento64)
Element to which refers Event Type
StartEvMacro (NoConfig,Macro1..Macro36)
Macro Configuration to execute at the start of event
OK
OK
Install Menu
20)Actions
Actions
Action 1
Action 1
Description
OK
Install Menu
21)Events
Events
Prog. Events
OK
OK
Prog. Events
Event 1
Event 1
Type
Summary of Contents for Synergy SY800