Installer Manual
Microvideo srl
www.microvideo.eu
51
CHAPTER 4– Programming Control Panel
EndEv.Macro
(NoConfig,Macro1..Macro36)
Macro Configuration to execute at the end of event
Special Events
Some Events are more critical than others, for this they are preset in the system and you
need only to configure the Activation and Restore Macros:
Special Event
Description
Fof Machine Failure
Alarm that is generated when there is a Failure of the system modules Fog Cannons. Possibly the causes of
Failure are:
- Malfunctioning of Resistors
- Malfunctioning of Pumps
- Malfunction of the boiler
- Liquid finished
- Malfunctioning of the thermocouple
Low Fog machine liquid
Alarm that is generated when Liquid for fog generation in fog machine modules is lower than 20%.
Negligence
Alarm that is generated when Plant is disarmed. It occurs when for a specific time (given in general
parameters), in NOT armed Status, the zone NEVER changes its Status
Radio Low Battery Alarm
Low battery alarm in radio elements (Radio Modules and Remote Controls)
Radio Dimming Alarm
Dimming alarm of at least one of the two radio bands used by the system (433Mhz o 868 Mhz)
Tamper
Lack communication with a satellite module (Keyboards, Expansions, Proximity Readers, GSM) due to cutting
wire, short circuit or fault on the CAN BUS
Low Battery
Battery fault of the Central disconnected, broken, download
No Electric Net
Lack Electric Network 220V
Robbery
Alarm of a zone programmed as Robbery
Coercion
Login via user code whose last digit is incremented by one (if the last digit is 9, the digit 0 digit is incremented)
Tamper Alarm
Control Unit Tampering and the various modules (Keyboards, Proximity Readers, Expansions, GSM) signaled
by the opening of its tamper Snatch or Tamper
GSM Damage
The control unit performs continuous monitoring of mobile network and GSM module and in the event of
network failure or fault of the module it runs the associated MACRO
Fuses Damage
The control unit performs continuously checks of various fuses mounted on The unit and on Expansions
Firefighting
Activating a zone programmed as Firefighting
Panic
Activating a zone programmed as Panic
Parameter
Options
Description
Fog machine Failure
Initial Macro
(NoConfig,Macro1..Macro36)
Initial Macro Configuration
Final Macro
(NoConfig,Macro1..Macro36)
Final Macro Configuration
Low Fog machine liquid
Initial Macro
(NoConfig,Macro1..Macro36)
Initial Macro Configuration
Final Macro
(NoConfig,Macro1..Macro36)
Final Macro Configuration
Negligence
Initial Macro
(NoConfig,Macro1..Macro36)
Initial Macro Configuration
Final Macro
(NoConfig,Macro1..Macro36)
Final Macro Configuration
RadioLowBattery
Initial Macro
(NoConfig,Macro1..Macro36)
Initial Macro Configuration
Final Macro
(NoConfig,Macro1..Macro36)
Final Macro Configuration
Dimming
Initial Macro
(NoConfig,Macro1..Macro36)
Initial Macro Configuration
Final Macro
(NoConfig,Macro1..Macro36)
Final Macro Configuration
Tamper
Initial Macro
(NoConfig,Macro1..Macro36)
Initial Macro Configuration
Final Macro
(NoConfig,Macro1..Macro36)
Final Macro Configuration
Low Battery
Initial Macro
(NoConfig,Macro1..Macro36)
Initial Macro Configuration
Final Macro
(NoConfig,Macro1..Macro36)
Final Macro Configuration
NoNet
Initial Macro
(NoConfig,Macro1..Macro36)
Initial Macro Configuration
Final Macro
(NoConfig,Macro1..Macro36)
Final Macro Configuration
Robbery
Initial Macro
(NoConfig,Macro1..Macro36)
Initial Macro Configuration
Final Macro
(NoConfig,Macro1..Macro36)
Final Macro Configuration
Coercion
Initial Macro
(NoConfig,Macro1..Macro36)
Initial Macro Configuration
Final Macro
(NoConfig,Macro1..Macro36)
Final Macro Configuration
OK
OK
OK
Install Menu
21)Events
Events
SpecialEvents
SpecialEvents
TAMPER
TAMPER
Initial Macro
Summary of Contents for Synergy SY800
Page 1: ...1 ...
Page 60: ...Installer Manual Microvideo srl www microvideo eu 60 ...