CHAPTER 4– Programming Control Panel
The maximum value of the reports is reset at each insertion of the plant
Keyboard ID
1..8
Keyboard ID
NOTE in keypads the address must be configured from Menu
ZONES
Parameter
Options
Description
Enable
Yes
Zone Enabled
No
Zone Disabled
Description
20 characters
Description of the zone. Description apprears during configuation: by Keyboard, by SynergyPro
SW, in logs, in SMS messages concerning the zone.
Exclusion Type
Auto-excludable
It represents a zone that can be temporarily Excluded (in a plant inserting) if it appears alarmed
during Area Arming
Not Excludible
You can never Exclude that zone, so you always must "estimate" it during Plant Arming
Termination
Ref "Installing
Sensors “Balance”
NO
Normalmente aperto
NO Bil
Normally Open Balanced
NC
Normally Closed
NC Bil
Normally Closed Balanced
NC DoubleBal
Bil
Normally closed Double Balance
NC TripleBal
Normally closed Triple Balance
Shutter
Shutter
ShutterBal
Balanced Shutter
InsImpImp
Impulsive Inserting System
InsImpLev
Inserting System on level
DelayTime
(0..65000)
Delay time (seconds) in the area if ZONE type is Delayed
NoInsNotReady
Yes
During Inserting System if this Zone is in alarm is Prevented the same Plant Equipment
No
The system can be armed (see "Type Exclusion" and " Forced Ins. ") even if this Zone is in alarm
during insertion system
Zone Type
Snapshot
The Zone, in case of unbalance, generates an alarm Immediatly
Delayed
The Zone, in case of unbalance, generates an alarm after delay time
Firefighting
ALWAYS armed Zone, every unbalance generates an alarm
Antirobbery
ALWAYS armed Zone, every unbalance generates an alarm
No Panic
ALWAYS armed Zone, every unbalance generates an alarm
24H
ALWAYS armed Zone, every unbalance generates an alarm
Technological
ALWAYS armed Zone, every unbalance generates an event, never alarms
Following Zone
If the Zone that must be chased is at rest the Following Zone behaves as "Snapshot"
If the Zone to chase is unbalanced the Following Zone takes time delay from the zone to chase
Alarm Cycle
(NoConfig,
0..127)
Alarm cycles after which the alarms of the Zone will be ignored for that specific insertion, however
they will continue to be saved to the Log
Pulse Count
(0..20)
Number of unbalancing in the area determining alarm state in case Termination is shutter or
shutter Balanced
Alarm Time
(0 ..3600)
Time (sec.) within which you must verify the count pulses to determine the state of alarm in case
the Termination is shutter or shutter Balanced
Areas
(Area1..Area12) Configuration of the areas the Zone belongs to
And/Or
AND
The Zone is inserted if ALL AREAS it belongs to are armed
OR
The Zone is inserted if LEAST one AREA it belongs to is armed
Test
Yes
Every alarm generation does not trigger any Event , but only Log
No
Every alarm generation triggers both Events and Logs
ZoneToChase
(Zone1..Zone73) If the zone is “following” type, this parameter indicates the zone that must be followed
(RadioZone1..
RadioZone64)
If the zone is “following” type, this parameter indicates the Radio zone that must be followed
Inser.Man. RL
(0...65000)
Value (ohm) Of RL Resistence ( Line Resistence)