6.28. Setting the Sync Sensor Sensitivity
This function serves to adjust the sensitivity of the Sync sensor
(photoelectric switch) to the gaps (perforations) of the actual used material.
Setting range for the sensitivity of the Sync sensor: 10 to 100 %.
The maximum sensitivity of 100 % has to be used for narrow gaps
(perforations). The minimum sensitivity of 10 % has to be used for clearly
detectable gaps.
The procedure of settings for this panel function [Sync.S.Sensitiv. ] is
similar to the panel function Contrast (Density) Setting (compare chapter
6.24).
Please pay attention to the following:
A too high level of sensitivity can lead to gaps being detected that do not
even exist (on proofs, material thickness fluctuations, perforations etc.).